The PSA (pressure swing adsorption) O2 generator uses the principle of pressure swing adsorption to stably and efficiently produce high-purity oxygen on offshore platforms. For cutting and welding work during offshore demolition, it can provide sufficient and high-purity oxygen sources to ensure strong flames, improve cutting and welding efficiency, and make demolition work go more smoothly. It is easy to operate and maintain, and can continue to work in harsh marine environments. With its sturdy design and reliable performance, it can resist seawater erosion and salt corrosion, providing strong guarantees for the safe and efficient advancement of offshore demolition operations.
Send Inquiry

Description

Technical Parameters

 

 

Working principle of PSA (pressure swing adsorption) O2 generator:

 


PSA O2 generator mainly works based on the principle of pressure swing adsorption. It is filled with special molecular sieve adsorbents. Under a certain pressure, different gas molecules will show different adsorption characteristics. When the raw air enters the generator, since impurity gas molecules such as nitrogen are more easily adsorbed by the molecular sieve than oxygen molecules, nitrogen is adsorbed on the surface of the molecular sieve under higher pressure, while oxygen molecules pass through relatively freely, thereby achieving oxygen separation. When the molecular sieve adsorption reaches saturation, the adsorbed nitrogen and other impurity gases are desorbed by reducing the pressure, so that the molecular sieve can restore its adsorption capacity, thereby achieving recycling. The entire process uses an automated pressure control system to alternately perform adsorption and desorption operations according to the set time and pressure program, continuously separating oxygen from the air, and finally producing high-purity oxygen. This oxygen production method has the advantages of simple operation, stable operation, and low maintenance cost, and can provide a continuous and reliable oxygen supply for offshore demolition operations.



 

learn more
psa o2 generator for offshore demolition

 

 

psa o2 generator for offshore demolition
How to ensure the stability of PSA O2 generator?

1. Equipment selection and installation
Reasonable installation layout: During installation, ensure that the foundation of the equipment is stable to avoid damage to the equipment due to vibration and shaking of the offshore platform. The pipe connection of the equipment should be tight and firm to prevent gas leakage. At the same time, ventilation and heat dissipation should be considered to avoid performance affected by overheating.
2. Operation and maintenance
Parameter monitoring and adjustment: Real-time monitoring of the operating parameters of the equipment, such as pressure, temperature, flow, etc. Through the data fed back by the sensor, the operating status of the equipment is evaluated, and the operating parameters, such as adsorption time, pressure change curve, etc., are adjusted in time as needed to ensure that the equipment is in the best working state.
3. Environmental adaptability
Temperature and humidity control: When possible, equip the equipment with corresponding temperature and humidity adjustment devices to ensure that its working environment temperature is within a suitable range (generally - 20℃ to 50℃) to prevent large fluctuations in temperature and humidity from affecting the performance of the equipment.
4. Safety guarantee
Multiple safety protection: Equipped with complete safety protection devices, such as overvoltage protection, undervoltage protection, overtemperature protection, etc. When an abnormal situation occurs, measures can be taken automatically, such as alarm and shutdown, to avoid equipment damage or safety accidents.

 


 

NTK93 Series PSA Oxygen Plant Model Selection
No. Models Capacity (Nm3/hr) Purity Power consumption of 1Nm3 oxygen produced (kw/h) Number of bottles filled in 12 hours (pcs) Operator needed
1 NTK-5P 5 93%+-3% 3.54 10 2
2 NTK-10P 10 93%+-3% 2.52 20 2
3 NTK-15P 15 93%+-3% 2.31 30 2
4 NTK-20P 20 93%+-3% 2.13 40 2
5 NTK-25P 25 93%+-3% 2.01 50 2
6 NTK-30P 30 93%+-3% 2.09 60 2
7 NTK-40P 40 93%+-3% 1.81 80 2
8 NTK-50P 50 93%+-3% 1.94 100 2
9 NTK-60P 60 93%+-3% 1.62 120 2
10 NTK-80P 80 93%+-3% 1.92 160 2
11 NTK-100P 100 93%+-3% 1.83 200 2
Design basis: Altitude:≤500m;RH:≤80%;Temperature:0℃-38℃;Filling pressure: 150Bar 40L Type Standard Cylinder



 

FAQ

 

1. Why should we choose high-quality molecular sieve adsorbents when selecting PSA O2 generator equipment?
High-quality molecular sieve adsorbents directly affect the oxygen separation effect and the long-term stability of the equipment. Its performance determines whether it can efficiently separate high-purity oxygen from the air and maintain stable performance in long-term operation, ensuring that the PSA O2 generator can continuously and reliably provide the required oxygen for offshore demolition operations.
 

2. How to operate and maintain the PSA O2 generator to ensure its performance?
A detailed maintenance plan should be formulated to regularly check the performance and life of the molecular sieve, replace the aged or degraded molecular sieve in time, and inspect and maintain the compressor, valves and other components. In addition, the operating parameters such as pressure, temperature, and flow are monitored in real time through sensors, and the equipment status is evaluated according to the feedback data and the operating parameters are adjusted in time, such as the adsorption time and pressure change curve, to ensure that the equipment is in the best working condition.

 

3. What is the impact of high humidity and high salinity in the offshore environment on the PSA O2 generator?
High humidity and high salinity may cause corrosion damage to the PSA O2 generator, affecting the performance and life of the equipment. Therefore, it is necessary to carry out anti-corrosion treatment on the shell and internal pipelines of the equipment, such as using anti-corrosion coating or using corrosion-resistant materials. At the same time, it is necessary to equip the temperature and humidity adjustment device to control the working environment temperature between -20℃ and 50℃ to prevent large fluctuations in temperature and humidity from affecting the performance of the equipment.

 

Hot Tags: psa o2 generator for offshore demolition, China psa o2 generator for offshore demolition , suppliers, factory, Psa Oxygen Plant