Application Of Oxygen Control Valves in Air Separation Units
Jul 07, 2025
Leave a message
Air separation units, as key auxiliary facilities in the petrochemical industry, supply oxygen to downstream units (such as ethylene oxide plants) through dedicated pipelines. The oxygen control valve, a core component of the delivery system, directly affects the safe and stable operation of both upstream and downstream units. Its failure could lead to unplanned shutdowns and significant economic losses. Therefore, strict control is required across multiple dimensions, including design and selection, application management, and manufacturer specifications.

Design and Selection Specifications for Oxygen Control Valves
Safety Settings for Actuator Handwheels
Oxygen control valves are typically installed inside firewalls for safety. Firewalls isolate deflagration risks to minimize harm to personnel and surrounding equipment. Operating handwheels inside firewalls is hazardous, as rapid operation may trigger deflagrations. Thus, control valves are generally designed without handwheels. If a handwheel is necessary, it must be installed outside the firewall with precise positioning. However, due to the difficulty of drilling holes in concrete firewalls, non-handwheel configurations are preferred to avoid operational risks.
Matching Principles for Materials and Flow Velocity
In oxygen service, high-velocity metal particles can easily cause deflagrations. Therefore, valve body and trim materials must be strictly matched to flow velocity and pressure. According to the European Industrial Gases Association (EIGA) standards, the product of oxygen pressure (absolute pressure) and flow velocity in impingement zones must meet specific limits, as shown in Table 1:
| Absolute Pressure (MPa) | Flow Velocity Limit for Non-Exempt Materials | Flow Velocity Limit for Exempt Materials |
|---|---|---|
| 0.3~1.5 | ≤30 m/s | Unrestricted |
| 1.5~10.0 | Pressure × Velocity ≤45.0 MPa·m/s | Unrestricted |
| 10.0~20.0 | ≤4.5 m/s | Unrestricted |
| >20.0 | Not allowed | Unrestricted |
Non-exempt materials (e.g., ordinary stainless steel) must be used cautiously when absolute pressure exceeds 2.5 MPa.
Exempt materials (e.g., nickel-based alloys) are not restricted by flow velocity. The maximum exempt pressures for common exempt materials are listed in Table 2:
| Material Grade | Maximum Exempt Absolute Pressure (MPa) | Minimum Thickness (mm) |
|---|---|---|
| MONEL K400 | 20.68 | 0.762 |
| MONEL K500 | 20.68 | 0.762 |
| INCONEL 600 | 8.61 | 3.180 |
| INCONEL 625 | 6.90 | 1.380 |
Selection of Valve Type and Trim
●Oxygen export control valves: For high flow and low pressure differentials, triple-offset butterfly valves are used, which provide both regulation and shut-off functions with a leakage class of at least ANSI FCI 70.2 CLASS V.
●Oxygen vent control valves: For high flow and large pressure differentials, cage-guided globe valves are selected to ensure rapid venting during abnormal conditions.
●Trim requirements: Valve stems and cages are designed for low friction to reduce wear and leakage. Gaskets must be metal-wound with graphite certified by authorized bodies. Components with high mean time to failure (MTTF) are prioritized to ensure long-term operation without bypass valves.
Special Requirements for Bonnet and Lubrication
Valve bonnets must be tightly sealed to prevent lubricants from seeping into the valve interior from gearboxes or yokes. Lubricants used in actuators must be certified by organizations such as Germany's BAM or the U.S.'s WHA to ensure oxygen compatibility. Non-metallic components (e.g., gaskets, packing) must also meet oxygen compatibility standards.
Noise Reduction and Flow Path Design for Valve Outlets
Oxygen vent valves often operate with large pressure differentials (>2.0 MPa) and require silencers to control noise (typically ≤110 dB). Silencers should handle 0.8~1.0 MPa of differential pressure. For low silencer differential pressure, control valves can use a reducing design (smaller inlet, larger outlet) to minimize flow path turbulence and reduce the number of pipe reducers.
Application Management Requirements
Core Standards for Oxygen Cleaning
Oxygen systems strictly prohibit oil residues. Control valves must undergo rigorous oxygen cleaning (degreasing) to ensure:
Oil content ≤125 mg per square meter, with no impurities exceeding 1 mm in diameter.
Cleaning is performed before assembly using solvents like carbon tetrachloride. Cleaned components must be air-dried, stored separately, and handled without oil contamination during assembly.
Inspection and Maintenance After Cleaning
●Inspection methods: Ultraviolet testing or wiping with lint-free cloths to verify oil content compliance.
●Subsequent maintenance: After passing inspection, assembly and testing must maintain oil-free conditions. Contamination requires re-cleaning.
Specifications for Packaging, Transportation, and Installation
●Packaging: Independent packaging with clear "oxygen-cleaned" labels, separated from oil-containing materials.
●Transportation and storage: Stored in dedicated oil-free areas to prevent contamination.
●Installation requirements: On-site warning signs for oil prohibition; installers and tools must be oil-free. If lubricants are necessary, only oxygen-compatible certified products are allowed. Post-installation, valves must be labeled as oil-free, with restricted access to non-professionals.
Technical Requirements for Manufacturers
To ensure valve quality, manufacturers must provide the following documents:
Detailed component drawings, indicating part names and quantities of non-metallic components.
Complete lists of non-metallic materials and lubricants.
Oxygen compatibility certification reports for non-metallic materials and lubricants.
Cleaning procedures (including methods for cleaning, assembly, testing, and cleanliness inspection).
Inspection and testing plans (including component cleanliness reports and storage protocols).
Conclusion
The safe and stable operation of oxygen control valves depends on strict adherence to standards throughout design, material selection, cleaning, inspection, installation, maintenance, and manufacturer oversight. Comprehensive compliance across these stages ensures long-term reliability of air separation units and downstream systems, minimizing safety risks and economic losses.